Blank Wall Plate
-
-
QUICKTRONIC High Efficiency, (QHE) energy-saving electronic T8 ballasts offer several advantages. Offers the Same Light, Less Power. Up to 6% in energy savings compared to standard T8 low power electronic ballasts without compromising light output. Parallel Circuitry keeps remaining lamps lit if 1 or more go out. Lamp Striation Control (LSC): T8 energy saving lamps should be operated above 60°F, but under certain conditions the lamps may striate. LSC circuitry may minimize or eliminate this condition, however there are limited applications where LSC circuitry may not entirely mitigate lamp striations.
-
Keystone Technology's T8 Instant Start electronic ballast is designed to operate 2 T8 lamps. Featuring 120-Volt to 277-Volt input and high-power factor design
-
This is a 2-Lamp 32-Watt T8 instant start electronic ballast. It has normal ballast factor. It is instant start and universal voltage.
-
70.0 MF 370 440 RA2000/37 44-706 +/-10%
-
Double-pole 120/240 volts Interchangeable circuit breaker SIZE: 60 Amp
-
3/4" wide per pole type CH breaker w/sandalwood handles marked with ON/Off indication & Amp Primary function is to protect the wire from overheating (overload) and fault currents (referred to as short circuits) 120/240V - 10 kAIC Meets UL 489, CSA & NEMA standards Lifetime warranty SIZE: 60 Amp - 2-Pole
-
Type CHF 3/4" GFI circuit breaker 20 Amp single pole Features trip flag indicator Includes self test feature Provides superior safety over a standard electric al outlet in areas where electricity may come into contact with water Great for bathrooms, swimming pools & hot tubs SIZE: 20 Amp COLOR: Black/Tan
-
CUTLER HAMMER INC ( EATON ELECTRIC) 1" wide per pole - molded case - Type BR Primary function is to protect the wire from overheating because of overload or fault currents (referred to as short circuits) Toggle type handle position indicates trip 120/240V AC - 10,000 AIC Meet UL 489, CSA & NEMA standards Carry listing for HCAR application SIZE: 60 Amp - 2-Pole
-
CUTLER HAMMER INC ( EATON ELECTRIC) 1" wide per pole - molded case - Type BR Primary function is to protect the wire from overheating because of overload or fault currents (referred to as short circuits) Toggle type handle position indicates trip 120/240V AC - 10,000 AIC Meet UL 489, CSA & NEMA standards Carry listing for HCAR application SIZE: 15 Amp - 1-Pole PACK TYPE: Bulk Pack
-
Thick double pole replacement circuit breaker For Federal Pacific electric type NA (thick) breakers 10,000 AIC - 2-pole ETL Listed SIZE: 30 Amp